Notice of Specification Change of Wired Touch Probe K3S Series
Dear Valued Customer,
Thank you very much for your continued support and patronage.
We would like to inform you that we will be making changes to the specifications of our wired Touch Probe K3S series to reflect improvements in quality and measures to reduce environmental impact, as detailed below. The timing of these specification changes is also noted below.
We sincerely apologize for any inconvenience this may cause and appreciate your understanding.
We look forward to your continued support of METROL products.
Change Details
- Applicable Product: Touch Probe K3S Series*1
(*1: All models starting with "K3S" are included. Example of model: K3S-I-001S)
- Timing of Specification Changes: For orders received on or after May 1, 2025
Before change | After change | |
---|---|---|
Contact Force [N] | 0.5 - 0.75 | 0.3 - 0.6 |
Stroke [° ] [mm] *Refer to the figure below | ± 9° 4.82mm | ± 7° 3.75mm |