Standard product
|
P12DLB-AL |
|
Contact structure
|
Dry contact |
|
Output mode
|
B:NC |
|
IP code / protective structure
|
IP67 |
|
With / without LED
|
with LED |
|
Repeatability
|
0.5μm |
|
Movement differential (mm)
|
0 |
|
Overall length
|
66mm |
|
Outer diameter
|
10×18×39 |
|
End shape
|
Round shape |
|
Shape of contacting part
|
φ8.5 plunger, Sφ2 |
|
Stroke
|
10mm |
|
How to use
|
Straight |
|
Contact force
|
1N |
|
Performance
|
water-resistance/dustproofing (IP67) |
|
Case material
|
BsBM+Ni plating |
|
Contact material
|
Tungsten carbide |
|
Bearing, type
|
Metal bearing |
|
Cable type
|
Cabtyre cable |
|
Cable specifications
|
Standard length 3 m Oil resistant φ5 / 2 cores,Tensile strength 30N |
|
Cable direction
|
Straight |
|
AWG
|
30 |
|
Contact life time
|
3 million |
|
Operating temperature range
|
0°C-80°C (ice-free) |
|
Temperature drift
|
No temperature drift due to self-generation. |
|
Oscillation
|
10-55Hz total amplitude 1.5 for X,Y,Z each direction |
|
Impact
|
300m/s2 for X,Y,Z each direction |
|
Contact rating
|
DC5V - DC24V Steady Current: 10 mA or less (Rush Current: 20 mA or less)
Limit the LED forward current below 10mA. |
P12DLB-AL
The blue line part can be customized. Please refer to our brochure for details.